This website uses cookies for function, comfort and statistical purposes. By clicking on “Change”, you can change the cookie settings at any time. If you agree to the use of cookies, please click “Agree”.

Change
  • Compensates for brief power peaks
  • Reduces water entrainment and counteracts its negative effects
  • Reduces switching frequency of steam generator
  • Reduces energy consumption and wear

Further information

This module is used for storing a defined quantity of energy which becomes available as expansion steam during pressure reduction. It is used for accommodating peak loads, e.g. if the capacity of a steam generator is exceeded briefly. The greater the water content of the accumulator, the greater the re-evaporation heat.

The steam accumulator consists of a horizontal cylindrical container with a built-in steam nozzle pipe.

The module is thermally insulated and supplied with equipment pre-fitted, ready for operation. The module is fitted with a venting, drain shut-off, filling shut-off, steam inlet and outlet valve, an overflow and overpressure valve, a direct temperature indicator and a water level display.